SMART CAT5 SWITCH 16 IP. Menu Work area Figure 5 The Smart 16 IP Home page 9. 10. Timeout After half an hour of non-activity the system automatically
OPERATING GUIDE. Information bar Control buttons Computer buttons Figure 6 The remote console You can work on it with the keyboard and mouse. The d
SMART CAT5 SWITCH 16 IP. In case Smart 16 IP is connected to your local network environment and your connection to the Internet is available using a p
OPERATING GUIDE. Mouse handling - The submenu for mouse handling offers 3 options for synchronizing the host and the client mouse pointer - explained
SMART CAT5 SWITCH 16 IP. Figure 7 Chat window All messages are broadcast to ALL connected users. There is no option to direct a message to a particul
OPERATING GUIDE. - Resets mode to factory defaults. - Resets all modes to factory defaults. - Saves changes. - Undoes changes that have not yet be
SMART CAT5 SWITCH 16 IP. 3. Windows XP has a setting 'enhanced pointer precision'. Deactivate it. 4. Active Desktop. Disable it. Or do not
OPERATING GUIDE. Fix – Choose the connection method. Automatic Detection - The encoding and the compression level is determined automatically from the
SMART CAT5 SWITCH 16 IP. Mouse hotkey - Used for fast mouse synchronization in Double Mouse mode and to free the grabbed mouse when in single mouse mo
OPERATING GUIDE. After reading all entries, Smart 16 IP displays them with their time, sensor and description in accordance with the filter settings.
SMART CAT5 SWITCH 16 IP. Table of Contents 1. Introduction ...
SMART CAT5 SWITCH 16 IP. Note: The prerequisite for the remote power/reset button to work is a correct installation of Smart 16 IP. External power If
OPERATING GUIDE. 20. If IPMI is disabled, the power control functions are performed through the internal or external power control options. 25. Keyb
SMART CAT5 SWITCH 16 IP. Targeted KVM port 1. Choose the port to which a KVM switch is connected. 2. Press to display the current values for the s
OPERATING GUIDE. Figure 13 KVM Settings The elements of the KVM Settings are explained below. Active Port To switch to a computer: 1. Choose a numbe
SMART CAT5 SWITCH 16 IP. Figure 14 KVM Port Settings 27. KVM Port Settings 1. Assign names for each port. 2. Define hotkeys to switch to each por
OPERATING GUIDE. Show in console – check this option to have a button appear on the top of the Remote console. Click the button to switch to that comp
SMART CAT5 SWITCH 16 IP. Click Add Custom Video Modes. The Custom Video Modes window appears, see Figure 16. Note! This option may affect the correct
OPERATING GUIDE. Description Give the mode a name. The name appears in the Remote Console when the custom mode is activated. 33. User/Group Managemen
SMART CAT5 SWITCH 16 IP. 38. Email address /Mobile number These are optional. 39. 40. 41. 42. 43. 44. Group membership/Member of/Not Member of Each
OPERATING GUIDE. 45. Copy User To copy an existing user’s properties to a new user: 1. Select a user in the Existing user Drop-down list. 2. Enter
OPERATING GUIDE. 45. Copy User ...
SMART CAT5 SWITCH 16 IP. Figure 18 User/Group Permissions Each user or group has a set of access rights to the Smart 16 IP functions. The user '
OPERATING GUIDE. Using a function. allow access means you can use it. deny access means you cannot use it. Group setting – Use the access rights inher
SMART CAT5 SWITCH 16 IP. IP auto configuration Choose between the 3 options. None – no IP auto configuration. In this case type a static IP address in
OPERATING GUIDE. Remote Console & HTTPS port Port number at which Smart 16 IP's Remote Console server and HTTPS server are listening. If emp
SMART CAT5 SWITCH 16 IP. Smart 16 IP is reachable via the IP address of the DSL router, which is dynamically assigned by the provider. Since the admin
OPERATING GUIDE. Smart 16 IP has its own independent real time clock. Ensure the time setting is correct by configuring a timeserver see page 22. Sma
SMART CAT5 SWITCH 16 IP. Modem Init String - Initialization string. The default value works with all modern standard modems connected to a telephone l
OPERATING GUIDE. Figure 23 External Power Option for Serial port 1 window Serial Port 2 This port provides the power control options, see page 18. C
SMART CAT5 SWITCH 16 IP. a username and password, which exist on the SPC and have the privileges to switch power for each port. Intelligent Power Mod
OPERATING GUIDE. Off - No encrypting used. Try - Tries to make an encrypted connection. If unsuccessful, an unencrypted connection is used. Force -
SMART CAT5 SWITCH 16 IP. 85. Connecting the RS232 Serial cable... 64 86
SMART CAT5 SWITCH 16 IP. You can generate and install a new certificate unique to a particular card. Smart 16 IP can generate a new cryptographic key
OPERATING GUIDE. 3. Click . 4. Press Download CSR to download the CSR to your administration machine. 5. Send the CSR to a CA for certification.
SMART CAT5 SWITCH 16 IP. NOTE: The order of the rules is important. The rules are checked in ascending order until a rule matches. Rules below the mat
OPERATING GUIDE. 56. SNMP Settings The following information is available via SNMP: • Serial number • Firmware version • MAC address / IP addr
SMART CAT5 SWITCH 16 IP. Figure 27 SNMP settings You can change the following parameters: Enable SNMP Agent - When checked, Smart 16 IP will answer t
OPERATING GUIDE. Trap destinations Enter IP addresses, to which the traps will be sent. For every IP address, set an according community so that you
SMART CAT5 SWITCH 16 IP. IPMI over Serial - If your host system supports IPMI V1.5 and has an Intel EMP (Emergency Management Port, usually COM2) conn
OPERATING GUIDE. values for the LDAP schema are set appropriately. Choose between Generic LDAP Server, Novell Directory Service and Microsoft Active D
SMART CAT5 SWITCH 16 IP. 3. Press the Update button. The firmware updates. Warning! This process is irreversible; ensure the Smart 16 IP's power
OPERATING GUIDE. 65. Telnet server commands Click help to list the following commands: cls - Clears screen quit - Logs out current user and disconne
OPERATING GUIDE. 1. 2. 3. 4. Introduction The sections below explain how to configure and operate the Smart CAT5 Switch 16 IP (Smart 16 IP) system rem
SMART CAT5 SWITCH 16 IP. 66. Frequently Asked Questions Q 1: The remote mouse doesn't work or is not synchronized. A: Ensure the Smart 16 IP m
OPERATING GUIDE. 67. Glossary of terms ACPI - A specification that enables the operating system to implement power management and system configuratio
SMART CAT5 SWITCH 16 IP. Appendix A: Smart 16 IP Video modes The Smart 16 IP supports the following video modes. Do not use other custom video settin
OPERATING GUIDE. Appendix B: Key codes Figure 31 illustrates the keys on a standard 104 key PC keyboard with a US English language mapping. These key
SMART CAT5 SWITCH 16 IP. Key Key code Alternative Scrl SCROLL_LOCK Brk BREAK Ins INSERT Pos1 HOME Pup PAGE_UP Del DELETE Pdn PA
OPERATING GUIDE. Appendix C: Operating the Smart 16 IP system locally Switch between the connected computers by either: • Keyboard hotkeys • The OS
SMART CAT5 SWITCH 16 IP. 70. Navigating the OSD To navigate up and down use the Up and Down arrow keys. To jump from one column to the next (when rel
OPERATING GUIDE. Figure 34 The General Settings window From this window you can do the following: Security The OSD comes with an advanced password se
SMART CAT5 SWITCH 16 IP. Activating password protection By default OSD access is not password protected. Only the Administrator can password-protect t
OPERATING GUIDE. To change the Serial port setting: 1. Navigate to the Serial port line. 2. Toggle between the options using the Space bar. Changing
SMART CAT5 SWITCH 16 IP. 3. Fill in the connection details. Select COM 1 in the Connect using box and click OK. The COM 1 properties box appears. See
SMART CAT5 SWITCH 16 IP. Editing the computer name In this window you can edit the computer names with up to 15 characters. To erase a character: Sel
OPERATING GUIDE. 76. The Time settings In the Settings window navigate to the Time line and press Enter. The Time settings window appears see Figure
SMART CAT5 SWITCH 16 IP. Figure 37 The Users settings window There are 3 different access levels. These are: • Y – Full access to a particular comp
OPERATING GUIDE. There can only be 1 Administrator password, 1 Supervisor password, and 6 User passwords. To change a user name or password: 1. Naviga
SMART CAT5 SWITCH 16 IP. 81. Tuning – F5 You can tune the image of any computer screen from the Select Computer window. To adjust the screen image: 1
OPERATING GUIDE. 84. Control software system requirements • Pentium 166 or higher computer • 16Mb RAM • Windows 98 and later • Free Serial port 8
SMART CAT5 SWITCH 16 IP. Figure 40 The Control window 87. Computer icons Icon Meaning Computer is connected and switched on Computer is switched
OPERATING GUIDE. Figure 41 Communication Error 89. 90. The View menu From the View menu choose to display: • All computers, or only active switched
SMART CAT5 SWITCH 16 IP. 94. Write Configuration With the Control software you can make changes to all OSD settings. You can then save these configur
OPERATING GUIDE. Figure 42 The logo Figure 43 The names and passwords 2. Make the desired changes. 3. Click OK. 98. Settings Choose Settings fr
OPERATING GUIDE. Figure 3 The Hyperterminal 6. Press Enter. Some device information and a prompt appear. 7. Type config and press Enter. Configura
SMART CAT5 SWITCH 16 IP. 4. Click OK. Single computer settings To see all the settings of a single computer, right click the computer icon. The setti
OPERATING GUIDE. To change the security access, close and reopen the Control software, and type in the different password. Administrator (Status A) T
SMART CAT5 SWITCH 16 IP. The Update software enables you to add new features and fix bugs in a quick and efficient manner. Install the Update software
OPERATING GUIDE. RICCs Smart Switch Status box Figure 46 The Smart CAT5 Switch Update window The table below explains the functions of the buttons a
SMART CAT5 SWITCH 16 IP. Figure 47 The Com Option box 3. Choose an available Com Port and click OK. Note! The RS232 Serial cable must be connected t
OPERATING GUIDE. To verify the RICC version number: 1. Open the Smart CAT5 Switch Update program. 2. Check one or more or all of the RICCs. 3. Cli
SMART CAT5 SWITCH 16 IP. Figure 48 The Open box 5. Open the file. 6. Click Start. The Smart CAT5 Switch Update flashes the firmware. On completion
OPERATING GUIDE. 113. Troubleshooting tips When using Firmware Update software you may sometimes get a Communication Error message. When updating a u
SMART CAT5 SWITCH 16 IP. Appendix D: USB SUN Combo keys The connected PS/2 keyboard does not have a special SUN keypad to perform special functions in
OPERATING GUIDE. 78. OPERATING GUIDE. 78.
SMART CAT5 SWITCH 16 IP. Host system mouse settings The host operating system has various settings for the mouse driver. Smart 16 IP works with accel
SMART CAT5 SWITCH 16 IP. 79.
OPERATING GUIDE. All the above interfaces are accessed using the TCP/IP protocol. They can thus be used via the built-in Ethernet adapter or modem. Th